Tomzn Tovpd1-60-ec Manual

Shut off the main circuit breaker before handling any wires.

: Once electrical conditions return to a safe range, the device automatically reconnects power after a user-defined delay. Fault Inquiry tomzn tovpd1-60-ec manual

TOMZN TOVPD1-60-EC Manual: Complete Installation, Programming, and Troubleshooting Guide Shut off the main circuit breaker before handling any wires

If no buttons are pressed for 10 seconds, the device saves all settings and exits to the home screen. Parameter Code Reference Table Adjustable Range Factory Default Over-voltage Action Delay Time 0.1s – 30s A2 Over-voltage Protection Value 230V – 300V A3 Over-voltage Recovery Value 225V – 295V A4 Power-on / Recovery Delay Time 1s – 500s A5 Under-voltage Action Delay Time 0.1s – 30s A6 Under-voltage Protection Value 140V – 210V A7 Under-voltage Recovery Value 145V – 215V A8 Over-current Action Delay Time 0.1s – 30s A9 Over-current Protection Value 1A – 60A Troubleshooting Common Faults 1. Device will not power on This link or copies made by others cannot be deleted

Class 1 electricity metering for precise tracking of energy usage. Configurable Protection Settings